COM Express Type 7 (Rev. 3.0) Pinout
PICMG COM Express COM.0 R3.0 Type 7 server-grade pinout specification for Basic (125×95 mm) and Extended (155×110 mm) modules featuring up to four 10GbE (10GBASE-KR) interfaces and 32 PCI Express lanes across two mezzanine connectors.
Aliase:COM Express, COM Express Type 7, COMe Type 7, COMe Basic, COMe Extended, COM.0 R3.0 Type 7, PICMG COM.0, Server-on-Module
COM Express Basic (125×95mm)
440 Pins
Pinout Table440
| Pin | Signal / Name | Type | Alternative Functions |
|---|---|---|---|
| A1 | GND | Ground | Signal and Power Ground Reference |
| A2 | GBE0_MDI3- | Digital | Gigabit Ethernet 0 MDI Differential Pair 3- |
| A3 | GBE0_MDI3+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 3+ |
| A4 | GBE0_LINK100# | Digital | Gigabit Ethernet 0 100 Mbps Link Indicator (Active Low) |
| A5 | GBE0_LINK1000# | Digital | Gigabit Ethernet 0 1000 Mbps Link Indicator (Active Low) |
| A6 | GBE0_MDI2- | Digital | Gigabit Ethernet 0 MDI Differential Pair 2- |
| A7 | GBE0_MDI2+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 2+ |
| A8 | GBE0_LINK# | Digital | Gigabit Ethernet 0 Link Active Indicator (Active Low) |
| A9 | GBE0_MDI1- | Digital | Gigabit Ethernet 0 MDI Differential Pair 1- |
| A10 | GBE0_MDI1+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 1+ |
| A11 | GND | Ground | Signal and Power Ground Reference |
| A12 | GBE0_MDI0- | Digital | Gigabit Ethernet 0 MDI Differential Pair 0- |
| A13 | GBE0_MDI0+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 0+ |
| A14 | GBE0_CTREF | Analog | Gigabit Ethernet Magnetics Center Tap Reference Voltage |
| A15 | SUS_S3# | Digital | ACPI S3 Suspend-to-RAM Sleep Control Output (Active Low) |
| A16 | SATA0_TX+ | Digital | Serial ATA Channel 0 Transmit Differential Pair (TX+) |
| A17 | SATA0_TX- | Digital | Serial ATA Channel 0 Transmit Differential Pair (TX-) |
| A18 | SUS_S4# | Digital | ACPI S4 Suspend-to-Disk Sleep Control Output (Active Low) |
| A19 | SATA0_RX+ | Digital | Serial ATA Channel 0 Receive Differential Pair (RX+) |
| A20 | SATA0_RX- | Digital | Serial ATA Channel 0 Receive Differential Pair (RX-) |
| A21 | GND | Ground | Signal and Power Ground Reference |
| A22 | PCIE_TX15+ | Digital | PCI Express Lane 15 Transmit Differential Pair (+) |
| A23 | PCIE_TX15- | Digital | PCI Express Lane 15 Transmit Differential Pair (-) |
| A24 | SUS_S5# | Digital | ACPI S5 Soft-Off Power State Control Output (Active Low) |
| A25 | PCIE_TX14+ | Digital | PCI Express Lane 14 Transmit Differential Pair (+) |
| A26 | PCIE_TX14- | Digital | PCI Express Lane 14 Transmit Differential Pair (-) |
| A27 | BATLOW# | Digital | Battery Low Voltage Input Indication from Carrier (Active Low) |
| A28 | SATA_ACT# | Digital | Serial ATA Activity Indicator LED (Open Collector Active Low) |
| A29 | RSVD | NC | Reserved Pin - Do Not Connect |
| A30 | RSVD | NC | Reserved Pin - Do Not Connect |
| A31 | GND | Ground | Signal and Power Ground Reference |
| A32 | RSVD | NC | Reserved Pin - Do Not Connect |
| A33 | RSVD | NC | Reserved Pin - Do Not Connect |
| A34 | BIOS_DIS0#/ESPI_SAFS | Digital | BIOS Boot Device Selection Strap 0 / eSPI Slave Attached Flash Sharing (SAFS) |
| A35 | THRMTRIP# | Digital | Processor Thermal Trip Catastrophic Over-temperature Output (Active Low) |
| A36 | PCIE_TX13+ | Digital | PCI Express Lane 13 Transmit Differential Pair (+) |
| A37 | PCIE_TX13- | Digital | PCI Express Lane 13 Transmit Differential Pair (-) |
| A38 | GND | Ground | Signal and Power Ground Reference |
| A39 | PCIE_TX12+ | Digital | PCI Express Lane 12 Transmit Differential Pair (+) |
| A40 | PCIE_TX12- | Digital | PCI Express Lane 12 Transmit Differential Pair (-) |
| A41 | GND | Ground | Signal and Power Ground Reference |
| A42 | USB2- | Digital | USB 2.0 Port 2 High-Speed Differential Data (-) |
| A43 | USB2+ | Digital | USB 2.0 Port 2 High-Speed Differential Data (+) |
| A44 | USB_2_3_OC# | Digital | USB Over-Current Fault Sense for Ports 2_3 (Active Low) |
| A45 | USB0- | Digital | USB 2.0 Port 0 High-Speed Differential Data (-) |
| A46 | USB0+ | Digital | USB 2.0 Port 0 High-Speed Differential Data (+) |
| A47 | VCC_RTC | Power | Real Time Clock Battery Power Input (+2.0V to +3.3V) |
| A48 | RSVD | NC | Reserved Pin - Do Not Connect |
| A49 | GBE0_SDP | Digital | Gigabit Ethernet 0 Software-Definable Pin (IEEE 1588 / 1PPS) |
| A50 | LPC_SERIRQ/ESPI_CS1# | Digital | LPC Serialized Interrupt Request / eSPI Secondary Chip Select 1 |
| A51 | GND | Ground | Signal and Power Ground Reference |
| A52 | PCIE_TX5+ | Digital | PCI Express Lane 5 Transmit Differential Pair (+) |
| A53 | PCIE_TX5- | Digital | PCI Express Lane 5 Transmit Differential Pair (-) |
| A54 | GPI0 | Digital | General Purpose Input 0 (Multiplexed with SD Card Data 0) |
| A55 | PCIE_TX4+ | Digital | PCI Express Lane 4 Transmit Differential Pair (+) |
| A56 | PCIE_TX4- | Digital | PCI Express Lane 4 Transmit Differential Pair (-) |
| A57 | GND | Ground | Signal and Power Ground Reference |
| A58 | PCIE_TX3+ | Digital | PCI Express Lane 3 Transmit Differential Pair (+) |
| A59 | PCIE_TX3- | Digital | PCI Express Lane 3 Transmit Differential Pair (-) |
| A60 | GND | Ground | Signal and Power Ground Reference |
| A61 | PCIE_TX2+ | Digital | PCI Express Lane 2 Transmit Differential Pair (+) |
| A62 | PCIE_TX2- | Digital | PCI Express Lane 2 Transmit Differential Pair (-) |
| A63 | GPI1 | Digital | General Purpose Input 1 (Multiplexed with SD Card Data 1) |
| A64 | PCIE_TX1+ | Digital | PCI Express Lane 1 Transmit Differential Pair (+) |
| A65 | PCIE_TX1- | Digital | PCI Express Lane 1 Transmit Differential Pair (-) |
| A66 | GND | Ground | Signal and Power Ground Reference |
| A67 | GPI2 | Digital | General Purpose Input 2 (Multiplexed with SD Card Data 2) |
| A68 | PCIE_TX0+ | Digital | PCI Express Lane 0 Transmit Differential Pair (+) |
| A69 | PCIE_TX0- | Digital | PCI Express Lane 0 Transmit Differential Pair (-) |
| A70 | GND | Ground | Signal and Power Ground Reference |
| A71 | PCIE_TX8+ | Digital | PCI Express Lane 8 Transmit Differential Pair (+) |
| A72 | PCIE_TX8- | Digital | PCI Express Lane 8 Transmit Differential Pair (-) |
| A73 | GND | Ground | Signal and Power Ground Reference |
| A74 | PCIE_TX9+ | Digital | PCI Express Lane 9 Transmit Differential Pair (+) |
| A75 | PCIE_TX9- | Digital | PCI Express Lane 9 Transmit Differential Pair (-) |
| A76 | GND | Ground | Signal and Power Ground Reference |
| A77 | PCIE_TX10+ | Digital | PCI Express Lane 10 Transmit Differential Pair (+) |
| A78 | PCIE_TX10- | Digital | PCI Express Lane 10 Transmit Differential Pair (-) |
| A79 | GND | Ground | Signal and Power Ground Reference |
| A80 | GND | Ground | Signal and Power Ground Reference |
| A81 | PCIE_TX11+ | Digital | PCI Express Lane 11 Transmit Differential Pair (+) |
| A82 | PCIE_TX11- | Digital | PCI Express Lane 11 Transmit Differential Pair (-) |
| A83 | GND | Ground | Signal and Power Ground Reference |
| A84 | NCSI_TX_EN | Digital | NC-SI Transmit Synchronous Enable Input |
| A85 | GPI3 | Digital | General Purpose Input 3 (Multiplexed with SD Card Data 3) |
| A86 | RSVD | NC | Reserved Pin - Do Not Connect |
| A87 | RSVD | NC | Reserved Pin - Do Not Connect |
| A88 | PCIE_CLK_REF+ | Digital | PCI Express 100 MHz Differential Reference Clock Output (+) |
| A89 | PCIE_CLK_REF- | Digital | PCI Express 100 MHz Differential Reference Clock Output (-) |
| A90 | GND | Ground | Signal and Power Ground Reference |
| A91 | SPI_POWER | Power | Dedicated +3.3V Power Output for Carrier SPI Flash |
| A92 | SPI_MISO | Digital | SPI Master In Slave Out - Serial Data from Carrier Flash to Module |
| A93 | GPO0 | Digital | General Purpose Output 0 (Multiplexed with SD Card Clock SD_CLK) |
| A94 | SPI_CLK | Digital | SPI Serial Clock Output from Module to Carrier BIOS Flash |
| A95 | SPI_MOSI | Digital | SPI Master Out Slave In - Serial Data from Module to Carrier Flash |
| A96 | TPM_PP | Digital | Trusted Platform Module (TPM) Physical Presence Hardware Input (Active High) |
| A97 | TYPE10# | Digital | Carrier Detection Strap for Type 10 Module (Pulled low with 47k on Type 10) |
| A98 | SER0_TX | Digital | General Purpose Asynchronous Serial Port 0 Transmit Serial Data Output |
| A99 | SER0_RX | Digital | General Purpose Asynchronous Serial Port 0 Receive Serial Data Input |
| A100 | GND | Ground | Signal and Power Ground Reference |
| A101 | SER1_TX | Digital | General Purpose Serial Port 1 / CAN Bus Transmit Serial Data Output (CAN_TX alternate) |
| A102 | SER1_RX | Digital | General Purpose Serial Port 1 / CAN Bus Receive Serial Data Input (CAN_RX alternate) |
| A103 | LID# | Digital | ACPI Notebook Lid Closure Switch Input (Active Low) |
| A104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A110 | GND | Ground | Signal and Power Ground Reference |
| B1 | GND | Ground | Signal and Power Ground Reference |
| B2 | GBE0_ACT# | Digital | Gigabit Ethernet 0 Activity Indicator (Active Low) |
| B3 | LPC_FRAME#/ESPI_CS0# | Digital | LPC Cycle Frame Indicator / eSPI Primary Chip Select 0 (Active Low) |
| B4 | LPC_AD0/ESPI_IO_0 | Digital | LPC Multiplexed Address/Data Bit 0 / eSPI Bidirectional I/O Bit 0 |
| B5 | LPC_AD1/ESPI_IO_1 | Digital | LPC Multiplexed Address/Data Bit 1 / eSPI Bidirectional I/O Bit 1 |
| B6 | LPC_AD2/ESPI_IO_2 | Digital | LPC Multiplexed Address/Data Bit 2 / eSPI Bidirectional I/O Bit 2 |
| B7 | LPC_AD3/ESPI_IO_3 | Digital | LPC Multiplexed Address/Data Bit 3 / eSPI Bidirectional I/O Bit 3 |
| B8 | LPC_DRQ0#/ESPI_ALERT0# | Digital | LPC DMA Request 0 / eSPI Alert 0 (Active Low) |
| B9 | LPC_DRQ1#/ESPI_ALERT1# | Digital | LPC DMA Request 1 / eSPI Alert 1 (Active Low) |
| B10 | LPC_CLK/ESPI_CK | Digital | LPC Bus 33 MHz Clock Output / eSPI Bus Clock |
| B11 | GND | Ground | Signal and Power Ground Reference |
| B12 | PWRBTN# | Digital | Power Button Input (Active Low falling edge, wakes system from S5) |
| B13 | SMB_CK | Digital | System Management Bus (SMBus) Bidirectional Clock Line |
| B14 | SMB_DAT | Digital | System Management Bus (SMBus) Bidirectional Data Line |
| B15 | SMB_ALERT# | Digital | System Management Bus (SMBus) Alert Interrupt Input (Active Low) |
| B16 | SATA1_TX+ | Digital | Serial ATA Channel 1 Transmit Differential Pair (TX+) |
| B17 | SATA1_TX- | Digital | Serial ATA Channel 1 Transmit Differential Pair (TX-) |
| B18 | SUS_STAT#/ESPI_RESET# | Digital | System Suspend Status Output / eSPI Bus Reset (Active Low) |
| B19 | SATA1_RX+ | Digital | Serial ATA Channel 1 Receive Differential Pair (RX+) |
| B20 | SATA1_RX- | Digital | Serial ATA Channel 1 Receive Differential Pair (RX-) |
| B21 | GND | Ground | Signal and Power Ground Reference |
| B22 | PCIE_RX15+ | Digital | PCI Express Lane 15 Receive Differential Pair (+) |
| B23 | PCIE_RX15- | Digital | PCI Express Lane 15 Receive Differential Pair (-) |
| B24 | PWR_OK | Digital | Power OK Status Input from Carrier Power Supply (+3.3V/+5V/+12V within regulation) |
| B25 | PCIE_RX14+ | Digital | PCI Express Lane 14 Receive Differential Pair (+) |
| B26 | PCIE_RX14- | Digital | PCI Express Lane 14 Receive Differential Pair (-) |
| B27 | WDT | Digital | Hardware Watchdog Timer Timeout Output Event |
| B28 | RSVD | NC | Reserved Pin - Do Not Connect |
| B29 | RSVD | NC | Reserved Pin - Do Not Connect |
| B30 | RSVD | NC | Reserved Pin - Do Not Connect |
| B31 | GND | Ground | Signal and Power Ground Reference |
| B32 | SPKR | Digital | PC Speaker Tone Generator Digital Output |
| B33 | I2C_CK | Digital | General Purpose Multi-Master I2C Bus Clock Output |
| B34 | I2C_DAT | Digital | General Purpose Multi-Master I2C Bus Bidirectional Data Line |
| B35 | THRM# | Digital | Thermal Alert Event Input to Module (Active Low) |
| B36 | PCIE_RX13+ | Digital | PCI Express Lane 13 Receive Differential Pair (+) |
| B37 | PCIE_RX13- | Digital | PCI Express Lane 13 Receive Differential Pair (-) |
| B38 | GND | Ground | Signal and Power Ground Reference |
| B39 | PCIE_RX12+ | Digital | PCI Express Lane 12 Receive Differential Pair (+) |
| B40 | PCIE_RX12- | Digital | PCI Express Lane 12 Receive Differential Pair (-) |
| B41 | GND | Ground | Signal and Power Ground Reference |
| B42 | USB3- | Digital | USB 2.0 Port 3 High-Speed Differential Data (-) |
| B43 | USB3+ | Digital | USB 2.0 Port 3 High-Speed Differential Data (+) |
| B44 | USB_0_1_OC# | Digital | USB Over-Current Fault Sense for Ports 0_1 (Active Low) |
| B45 | USB1- | Digital | USB 2.0 Port 1 High-Speed Differential Data (-) |
| B46 | USB1+ | Digital | USB 2.0 Port 1 High-Speed Differential Data (+) |
| B47 | ESPI_EN# | Digital | Carrier Strap to Enable eSPI Mode (Pulled to GND) vs LPC Mode (Unconnected) |
| B48 | USB0_HOST_PRSNT | Digital | USB Port 0 Client Host Presence Detection Input |
| B49 | SYS_RESET# | Digital | System Reset Button Input (Active Low request for system reboot) |
| B50 | CB_RESET# | Digital | Carrier Board Reset Output from Module (Active Low reset to carrier components) |
| B51 | GND | Ground | Signal and Power Ground Reference |
| B52 | PCIE_RX5+ | Digital | PCI Express Lane 5 Receive Differential Pair (+) |
| B53 | PCIE_RX5- | Digital | PCI Express Lane 5 Receive Differential Pair (-) |
| B54 | GPO1 | Digital | General Purpose Output 1 (Multiplexed with SD Card Command SD_CMD) |
| B55 | PCIE_RX4+ | Digital | PCI Express Lane 4 Receive Differential Pair (+) |
| B56 | PCIE_RX4- | Digital | PCI Express Lane 4 Receive Differential Pair (-) |
| B57 | GPO2 | Digital | General Purpose Output 2 (Multiplexed with SD Card Write Protect SD_WP) |
| B58 | PCIE_RX3+ | Digital | PCI Express Lane 3 Receive Differential Pair (+) |
| B59 | PCIE_RX3- | Digital | PCI Express Lane 3 Receive Differential Pair (-) |
| B60 | GND | Ground | Signal and Power Ground Reference |
| B61 | PCIE_RX2+ | Digital | PCI Express Lane 2 Receive Differential Pair (+) |
| B62 | PCIE_RX2- | Digital | PCI Express Lane 2 Receive Differential Pair (-) |
| B63 | GPO3 | Digital | General Purpose Output 3 (Multiplexed with SD Card Card Detect SD_CD#) |
| B64 | PCIE_RX1+ | Digital | PCI Express Lane 1 Receive Differential Pair (+) |
| B65 | PCIE_RX1- | Digital | PCI Express Lane 1 Receive Differential Pair (-) |
| B66 | WAKE0# | Digital | PCI Express Bus Wake-up Event Input (Active Low) |
| B67 | WAKE1# | Digital | General Purpose Wake-up Event Input (Active Low) |
| B68 | PCIE_RX0+ | Digital | PCI Express Lane 0 Receive Differential Pair (+) |
| B69 | PCIE_RX0- | Digital | PCI Express Lane 0 Receive Differential Pair (-) |
| B70 | GND | Ground | Signal and Power Ground Reference |
| B71 | PCIE_RX8+ | Digital | PCI Express Lane 8 Receive Differential Pair (+) |
| B72 | PCIE_RX8- | Digital | PCI Express Lane 8 Receive Differential Pair (-) |
| B73 | GND | Ground | Signal and Power Ground Reference |
| B74 | PCIE_RX9+ | Digital | PCI Express Lane 9 Receive Differential Pair (+) |
| B75 | PCIE_RX9- | Digital | PCI Express Lane 9 Receive Differential Pair (-) |
| B76 | GND | Ground | Signal and Power Ground Reference |
| B77 | PCIE_RX10+ | Digital | PCI Express Lane 10 Receive Differential Pair (+) |
| B78 | PCIE_RX10- | Digital | PCI Express Lane 10 Receive Differential Pair (-) |
| B79 | GND | Ground | Signal and Power Ground Reference |
| B80 | GND | Ground | Signal and Power Ground Reference |
| B81 | PCIE_RX11+ | Digital | PCI Express Lane 11 Receive Differential Pair (+) |
| B82 | PCIE_RX11- | Digital | PCI Express Lane 11 Receive Differential Pair (-) |
| B83 | GND | Ground | Signal and Power Ground Reference |
| B84 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B85 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B86 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B87 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B88 | BIOS_DIS1# | Digital | BIOS Boot Device Selection Strap 1 Input |
| B89 | NCSI_RX_ER | Digital | NC-SI Receive Error Output |
| B90 | GND | Ground | Signal and Power Ground Reference |
| B91 | NCSI_CLK_IN | Digital | NC-SI 50 MHz Interface Reference Clock Input |
| B92 | NCSI_RXD1 | Digital | NC-SI Receive Data Bit 1 (Network Controller to BMC) |
| B93 | NCSI_RXD0 | Digital | NC-SI Receive Data Bit 0 (Network Controller to BMC) |
| B94 | NCSI_CRS_DV | Digital | NC-SI Carrier Sense / Receive Data Valid Output |
| B95 | NCSI_TXD1 | Digital | NC-SI Transmit Data Bit 1 (BMC to Network Controller) |
| B96 | NCSI_TXD0 | Digital | NC-SI Transmit Data Bit 0 (BMC to Network Controller) |
| B97 | SPI_CS# | Digital | SPI Chip Select for Carrier Board BIOS Flash (Active Low) |
| B98 | NCSI_ARB_IN | Digital | NC-SI Hardware Arbitration Token Ring Input |
| B99 | NCSI_ARB_OUT | Digital | NC-SI Hardware Arbitration Token Ring Output |
| B100 | GND | Ground | Signal and Power Ground Reference |
| B101 | FAN_PWMOUT | Digital | Pulse Width Modulated Fan Speed Control Output |
| B102 | FAN_TACHIN | Digital | Fan Tachometer Speed Sensor Input (Two pulses per revolution) |
| B103 | SLEEP# | Digital | ACPI Sleep Button / Hibernate Switch Input (Active Low) |
| B104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B110 | GND | Ground | Signal and Power Ground Reference |
| C1 | GND | Ground | Signal and Power Ground Reference |
| C2 | GND | Ground | Signal and Power Ground Reference |
| C3 | USB_SSRX0- | Digital | USB 3.0 SuperSpeed Port 0 Receive Differential Pair (-) |
| C4 | USB_SSRX0+ | Digital | USB 3.0 SuperSpeed Port 0 Receive Differential Pair (+) |
| C5 | GND | Ground | Signal and Power Ground Reference |
| C6 | USB_SSRX1- | Digital | USB 3.0 SuperSpeed Port 1 Receive Differential Pair (-) |
| C7 | USB_SSRX1+ | Digital | USB 3.0 SuperSpeed Port 1 Receive Differential Pair (+) |
| C8 | GND | Ground | Signal and Power Ground Reference |
| C9 | USB_SSRX2- | Digital | USB 3.0 SuperSpeed Port 2 Receive Differential Pair (-) |
| C10 | USB_SSRX2+ | Digital | USB 3.0 SuperSpeed Port 2 Receive Differential Pair (+) |
| C11 | GND | Ground | Signal and Power Ground Reference |
| C12 | USB_SSRX3- | Digital | USB 3.0 SuperSpeed Port 3 Receive Differential Pair (-) |
| C13 | USB_SSRX3+ | Digital | USB 3.0 SuperSpeed Port 3 Receive Differential Pair (+) |
| C14 | GND | Ground | Signal and Power Ground Reference |
| C15 | 10G_PHY_MDC_SCL3 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 3 |
| C16 | 10G_PHY_MDC_SCL2 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 2 |
| C17 | 10G_SDP2 | Digital | 10G Controller Software-Definable Pin 2 (IEEE 1588 1PPS) |
| C18 | GND | Ground | Signal and Power Ground Reference |
| C19 | PCIE_RX6+ | Digital | PCI Express Lane 6 Receive Differential Pair (+) |
| C20 | PCIE_RX6- | Digital | PCI Express Lane 6 Receive Differential Pair (-) |
| C21 | GND | Ground | Signal and Power Ground Reference |
| C22 | PCIE_RX7+ | Digital | PCI Express Lane 7 Receive Differential Pair (+) |
| C23 | PCIE_RX7- | Digital | PCI Express Lane 7 Receive Differential Pair (-) |
| C24 | 10G_INT2 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 2 |
| C25 | GND | Ground | Signal and Power Ground Reference |
| C26 | 10G_KR_RX3+ | Digital | 10GBASE-KR Port 3 Receive Input Differential Pair (+) |
| C27 | 10G_KR_RX3- | Digital | 10GBASE-KR Port 3 Receive Input Differential Pair (-) |
| C28 | GND | Ground | Signal and Power Ground Reference |
| C29 | 10G_KR_RX2+ | Digital | 10GBASE-KR Port 2 Receive Input Differential Pair (+) |
| C30 | 10G_KR_RX2- | Digital | 10GBASE-KR Port 2 Receive Input Differential Pair (-) |
| C31 | GND | Ground | Signal and Power Ground Reference |
| C32 | 10G_SFP_SDA3 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 3 |
| C33 | 10G_SFP_SDA2 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 2 |
| C34 | 10G_PHY_RST_23 | Digital | 10G Optical PHY Hardware Reset Output for Ports 23 (Active Low) |
| C35 | 10G_PHY_RST_01 | Digital | 10G Optical PHY Hardware Reset Output for Ports 01 (Active Low) |
| C36 | 10G_LED_SDA | Digital | 10G MAC LED and PHY Strapping Serialized I2C Bus Data |
| C37 | 10G_LED_SCL | Digital | 10G MAC LED and PHY Strapping Serialized I2C Bus Clock |
| C38 | 10G_SFP_SDA1 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 1 |
| C39 | 10G_SFP_SDA0 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 0 |
| C40 | 10G_SDP0 | Digital | 10G Controller Software-Definable Pin 0 (IEEE 1588 1PPS) |
| C41 | GND | Ground | Signal and Power Ground Reference |
| C42 | 10G_KR_RX1+ | Digital | 10GBASE-KR Port 1 Receive Input Differential Pair (+) |
| C43 | 10G_KR_RX1- | Digital | 10GBASE-KR Port 1 Receive Input Differential Pair (-) |
| C44 | GND | Ground | Signal and Power Ground Reference |
| C45 | 10G_PHY_MDC_SCL1 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 1 |
| C46 | 10G_PHY_MDC_SCL0 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 0 |
| C47 | 10G_INT0 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 0 |
| C48 | GND | Ground | Signal and Power Ground Reference |
| C49 | 10G_KR_RX0+ | Digital | 10GBASE-KR Port 0 Receive Input Differential Pair (+) |
| C50 | 10G_KR_RX0- | Digital | 10GBASE-KR Port 0 Receive Input Differential Pair (-) |
| C51 | GND | Ground | Signal and Power Ground Reference |
| C52 | PCIE_RX16+ | Digital | PCI Express Lane 16 Receive Differential Pair (+) |
| C53 | PCIE_RX16- | Digital | PCI Express Lane 16 Receive Differential Pair (-) |
| C54 | TYPE0# | Digital | Module Pin-out Type Identification Strap 0 Output to Carrier |
| C55 | PCIE_RX17+ | Digital | PCI Express Lane 17 Receive Differential Pair (+) |
| C56 | PCIE_RX17- | Digital | PCI Express Lane 17 Receive Differential Pair (-) |
| C57 | TYPE1# | Digital | Module Pin-out Type Identification Strap 1 Output to Carrier |
| C58 | PCIE_RX18+ | Digital | PCI Express Lane 18 Receive Differential Pair (+) |
| C59 | PCIE_RX18- | Digital | PCI Express Lane 18 Receive Differential Pair (-) |
| C60 | GND | Ground | Signal and Power Ground Reference |
| C61 | PCIE_RX19+ | Digital | PCI Express Lane 19 Receive Differential Pair (+) |
| C62 | PCIE_RX19- | Digital | PCI Express Lane 19 Receive Differential Pair (-) |
| C63 | RSVD | NC | Reserved Pin - Do Not Connect |
| C64 | RSVD | NC | Reserved Pin - Do Not Connect |
| C65 | PCIE_RX20+ | Digital | PCI Express Lane 20 Receive Differential Pair (+) |
| C66 | PCIE_RX20- | Digital | PCI Express Lane 20 Receive Differential Pair (-) |
| C67 | RAPID_SHUTDOWN | Digital | Emergency Rapid Shutdown Trigger Input for NV-DIMM / data protection |
| C68 | PCIE_RX21+ | Digital | PCI Express Lane 21 Receive Differential Pair (+) |
| C69 | PCIE_RX21- | Digital | PCI Express Lane 21 Receive Differential Pair (-) |
| C70 | GND | Ground | Signal and Power Ground Reference |
| C71 | PCIE_RX22+ | Digital | PCI Express Lane 22 Receive Differential Pair (+) |
| C72 | PCIE_RX22- | Digital | PCI Express Lane 22 Receive Differential Pair (-) |
| C73 | GND | Ground | Signal and Power Ground Reference |
| C74 | PCIE_RX23+ | Digital | PCI Express Lane 23 Receive Differential Pair (+) |
| C75 | PCIE_RX23- | Digital | PCI Express Lane 23 Receive Differential Pair (-) |
| C76 | GND | Ground | Signal and Power Ground Reference |
| C77 | RSVD | NC | Reserved Pin - Do Not Connect |
| C78 | PCIE_RX24+ | Digital | PCI Express Lane 24 Receive Differential Pair (+) |
| C79 | PCIE_RX24- | Digital | PCI Express Lane 24 Receive Differential Pair (-) |
| C80 | GND | Ground | Signal and Power Ground Reference |
| C81 | PCIE_RX25+ | Digital | PCI Express Lane 25 Receive Differential Pair (+) |
| C82 | PCIE_RX25- | Digital | PCI Express Lane 25 Receive Differential Pair (-) |
| C83 | RSVD | NC | Reserved Pin - Do Not Connect |
| C84 | GND | Ground | Signal and Power Ground Reference |
| C85 | PCIE_RX26+ | Digital | PCI Express Lane 26 Receive Differential Pair (+) |
| C86 | PCIE_RX26- | Digital | PCI Express Lane 26 Receive Differential Pair (-) |
| C87 | GND | Ground | Signal and Power Ground Reference |
| C88 | PCIE_RX27+ | Digital | PCI Express Lane 27 Receive Differential Pair (+) |
| C89 | PCIE_RX27- | Digital | PCI Express Lane 27 Receive Differential Pair (-) |
| C90 | GND | Ground | Signal and Power Ground Reference |
| C91 | PCIE_RX28+ | Digital | PCI Express Lane 28 Receive Differential Pair (+) |
| C92 | PCIE_RX28- | Digital | PCI Express Lane 28 Receive Differential Pair (-) |
| C93 | GND | Ground | Signal and Power Ground Reference |
| C94 | PCIE_RX29+ | Digital | PCI Express Lane 29 Receive Differential Pair (+) |
| C95 | PCIE_RX29- | Digital | PCI Express Lane 29 Receive Differential Pair (-) |
| C96 | GND | Ground | Signal and Power Ground Reference |
| C97 | RSVD | NC | Reserved Pin - Do Not Connect |
| C98 | PCIE_RX30+ | Digital | PCI Express Lane 30 Receive Differential Pair (+) |
| C99 | PCIE_RX30- | Digital | PCI Express Lane 30 Receive Differential Pair (-) |
| C100 | GND | Ground | Signal and Power Ground Reference |
| C101 | PCIE_RX31+ | Digital | PCI Express Lane 31 Receive Differential Pair (+) |
| C102 | PCIE_RX31- | Digital | PCI Express Lane 31 Receive Differential Pair (-) |
| C103 | GND | Ground | Signal and Power Ground Reference |
| C104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C110 | GND | Ground | Signal and Power Ground Reference |
| D1 | GND | Ground | Signal and Power Ground Reference |
| D2 | GND | Ground | Signal and Power Ground Reference |
| D3 | USB_SSTX0- | Digital | USB 3.0 SuperSpeed Port 0 Transmit Differential Pair (-) |
| D4 | USB_SSTX0+ | Digital | USB 3.0 SuperSpeed Port 0 Transmit Differential Pair (+) |
| D5 | GND | Ground | Signal and Power Ground Reference |
| D6 | USB_SSTX1- | Digital | USB 3.0 SuperSpeed Port 1 Transmit Differential Pair (-) |
| D7 | USB_SSTX1+ | Digital | USB 3.0 SuperSpeed Port 1 Transmit Differential Pair (+) |
| D8 | GND | Ground | Signal and Power Ground Reference |
| D9 | USB_SSTX2- | Digital | USB 3.0 SuperSpeed Port 2 Transmit Differential Pair (-) |
| D10 | USB_SSTX2+ | Digital | USB 3.0 SuperSpeed Port 2 Transmit Differential Pair (+) |
| D11 | GND | Ground | Signal and Power Ground Reference |
| D12 | USB_SSTX3- | Digital | USB 3.0 SuperSpeed Port 3 Transmit Differential Pair (-) |
| D13 | USB_SSTX3+ | Digital | USB 3.0 SuperSpeed Port 3 Transmit Differential Pair (+) |
| D14 | GND | Ground | Signal and Power Ground Reference |
| D15 | 10G_PHY_MDIO_SDA3 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 3 |
| D16 | 10G_PHY_MDIO_SDA2 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 2 |
| D17 | 10G_SDP3 | Digital | 10G Controller Software-Definable Pin 3 (IEEE 1588 1PPS) |
| D18 | GND | Ground | Signal and Power Ground Reference |
| D19 | PCIE_TX6+ | Digital | PCI Express Lane 6 Transmit Differential Pair (+) |
| D20 | PCIE_TX6- | Digital | PCI Express Lane 6 Transmit Differential Pair (-) |
| D21 | GND | Ground | Signal and Power Ground Reference |
| D22 | PCIE_TX7+ | Digital | PCI Express Lane 7 Transmit Differential Pair (+) |
| D23 | PCIE_TX7- | Digital | PCI Express Lane 7 Transmit Differential Pair (-) |
| D24 | 10G_INT3 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 3 |
| D25 | RSVD | NC | Reserved Pin - Do Not Connect |
| D26 | 10G_KR_TX3+ | Digital | 10GBASE-KR Port 3 Transmit Output Differential Pair (+) |
| D27 | 10G_KR_TX3- | Digital | 10GBASE-KR Port 3 Transmit Output Differential Pair (-) |
| D28 | GND | Ground | Signal and Power Ground Reference |
| D29 | 10G_KR_TX2+ | Digital | 10GBASE-KR Port 2 Transmit Output Differential Pair (+) |
| D30 | 10G_KR_TX2- | Digital | 10GBASE-KR Port 2 Transmit Output Differential Pair (-) |
| D31 | GND | Ground | Signal and Power Ground Reference |
| D32 | 10G_SFP_SCL3 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 3 |
| D33 | 10G_SFP_SCL2 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 2 |
| D34 | 10G_PHY_CAP_23 | Digital | 10G PHY Configuration Mode Capability Input Strap for Ports 23 (Low: I2C/MDIO, High: MDIO only) |
| D35 | 10G_PHY_CAP_01 | Digital | 10G PHY Configuration Mode Capability Input Strap for Ports 01 (Low: I2C/MDIO, High: MDIO only) |
| D36 | RSVD | NC | Reserved Pin - Do Not Connect |
| D37 | RSVD | NC | Reserved Pin - Do Not Connect |
| D38 | 10G_SFP_SCL1 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 1 |
| D39 | 10G_SFP_SCL0 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 0 |
| D40 | 10G_SDP1 | Digital | 10G Controller Software-Definable Pin 1 (IEEE 1588 1PPS) |
| D41 | GND | Ground | Signal and Power Ground Reference |
| D42 | 10G_KR_TX1+ | Digital | 10GBASE-KR Port 1 Transmit Output Differential Pair (+) |
| D43 | 10G_KR_TX1- | Digital | 10GBASE-KR Port 1 Transmit Output Differential Pair (-) |
| D44 | GND | Ground | Signal and Power Ground Reference |
| D45 | 10G_PHY_MDIO_SDA1 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 1 |
| D46 | 10G_PHY_MDIO_SDA0 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 0 |
| D47 | 10G_INT1 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 1 |
| D48 | GND | Ground | Signal and Power Ground Reference |
| D49 | 10G_KR_TX0+ | Digital | 10GBASE-KR Port 0 Transmit Output Differential Pair (+) |
| D50 | 10G_KR_TX0- | Digital | 10GBASE-KR Port 0 Transmit Output Differential Pair (-) |
| D51 | GND | Ground | Signal and Power Ground Reference |
| D52 | PCIE_TX16+ | Digital | PCI Express Lane 16 Transmit Differential Pair (+) |
| D53 | PCIE_TX16- | Digital | PCI Express Lane 16 Transmit Differential Pair (-) |
| D54 | RSVD | NC | Reserved Pin - Do Not Connect |
| D55 | PCIE_TX17+ | Digital | PCI Express Lane 17 Transmit Differential Pair (+) |
| D56 | PCIE_TX17- | Digital | PCI Express Lane 17 Transmit Differential Pair (-) |
| D57 | TYPE2# | Digital | Module Pin-out Type Identification Strap 2 Output to Carrier |
| D58 | PCIE_TX18+ | Digital | PCI Express Lane 18 Transmit Differential Pair (+) |
| D59 | PCIE_TX18- | Digital | PCI Express Lane 18 Transmit Differential Pair (-) |
| D60 | GND | Ground | Signal and Power Ground Reference |
| D61 | PCIE_TX19+ | Digital | PCI Express Lane 19 Transmit Differential Pair (+) |
| D62 | PCIE_TX19- | Digital | PCI Express Lane 19 Transmit Differential Pair (-) |
| D63 | RSVD | NC | Reserved Pin - Do Not Connect |
| D64 | RSVD | NC | Reserved Pin - Do Not Connect |
| D65 | PCIE_TX20+ | Digital | PCI Express Lane 20 Transmit Differential Pair (+) |
| D66 | PCIE_TX20- | Digital | PCI Express Lane 20 Transmit Differential Pair (-) |
| D67 | GND | Ground | Signal and Power Ground Reference |
| D68 | PCIE_TX21+ | Digital | PCI Express Lane 21 Transmit Differential Pair (+) |
| D69 | PCIE_TX21- | Digital | PCI Express Lane 21 Transmit Differential Pair (-) |
| D70 | GND | Ground | Signal and Power Ground Reference |
| D71 | PCIE_TX22+ | Digital | PCI Express Lane 22 Transmit Differential Pair (+) |
| D72 | PCIE_TX22- | Digital | PCI Express Lane 22 Transmit Differential Pair (-) |
| D73 | GND | Ground | Signal and Power Ground Reference |
| D74 | PCIE_TX23+ | Digital | PCI Express Lane 23 Transmit Differential Pair (+) |
| D75 | PCIE_TX23- | Digital | PCI Express Lane 23 Transmit Differential Pair (-) |
| D76 | GND | Ground | Signal and Power Ground Reference |
| D77 | RSVD | NC | Reserved Pin - Do Not Connect |
| D78 | PCIE_TX24+ | Digital | PCI Express Lane 24 Transmit Differential Pair (+) |
| D79 | PCIE_TX24- | Digital | PCI Express Lane 24 Transmit Differential Pair (-) |
| D80 | GND | Ground | Signal and Power Ground Reference |
| D81 | PCIE_TX25+ | Digital | PCI Express Lane 25 Transmit Differential Pair (+) |
| D82 | PCIE_TX25- | Digital | PCI Express Lane 25 Transmit Differential Pair (-) |
| D83 | RSVD | NC | Reserved Pin - Do Not Connect |
| D84 | GND | Ground | Signal and Power Ground Reference |
| D85 | PCIE_TX26+ | Digital | PCI Express Lane 26 Transmit Differential Pair (+) |
| D86 | PCIE_TX26- | Digital | PCI Express Lane 26 Transmit Differential Pair (-) |
| D87 | GND | Ground | Signal and Power Ground Reference |
| D88 | PCIE_TX27+ | Digital | PCI Express Lane 27 Transmit Differential Pair (+) |
| D89 | PCIE_TX27- | Digital | PCI Express Lane 27 Transmit Differential Pair (-) |
| D90 | GND | Ground | Signal and Power Ground Reference |
| D91 | PCIE_TX28+ | Digital | PCI Express Lane 28 Transmit Differential Pair (+) |
| D92 | PCIE_TX28- | Digital | PCI Express Lane 28 Transmit Differential Pair (-) |
| D93 | GND | Ground | Signal and Power Ground Reference |
| D94 | PCIE_TX29+ | Digital | PCI Express Lane 29 Transmit Differential Pair (+) |
| D95 | PCIE_TX29- | Digital | PCI Express Lane 29 Transmit Differential Pair (-) |
| D96 | GND | Ground | Signal and Power Ground Reference |
| D97 | RSVD | NC | Reserved Pin - Do Not Connect |
| D98 | PCIE_TX30+ | Digital | PCI Express Lane 30 Transmit Differential Pair (+) |
| D99 | PCIE_TX30- | Digital | PCI Express Lane 30 Transmit Differential Pair (-) |
| D100 | GND | Ground | Signal and Power Ground Reference |
| D101 | PCIE_TX31+ | Digital | PCI Express Lane 31 Transmit Differential Pair (+) |
| D102 | PCIE_TX31- | Digital | PCI Express Lane 31 Transmit Differential Pair (-) |
| D103 | GND | Ground | Signal and Power Ground Reference |
| D104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D110 | GND | Ground | Signal and Power Ground Reference |
COM Express Extended (155×110mm)
440 Pins
Pinout Table440
| Pin | Signal / Name | Type | Alternative Functions |
|---|---|---|---|
| A1 | GND | Ground | Signal and Power Ground Reference |
| A2 | GBE0_MDI3- | Digital | Gigabit Ethernet 0 MDI Differential Pair 3- |
| A3 | GBE0_MDI3+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 3+ |
| A4 | GBE0_LINK100# | Digital | Gigabit Ethernet 0 100 Mbps Link Indicator (Active Low) |
| A5 | GBE0_LINK1000# | Digital | Gigabit Ethernet 0 1000 Mbps Link Indicator (Active Low) |
| A6 | GBE0_MDI2- | Digital | Gigabit Ethernet 0 MDI Differential Pair 2- |
| A7 | GBE0_MDI2+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 2+ |
| A8 | GBE0_LINK# | Digital | Gigabit Ethernet 0 Link Active Indicator (Active Low) |
| A9 | GBE0_MDI1- | Digital | Gigabit Ethernet 0 MDI Differential Pair 1- |
| A10 | GBE0_MDI1+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 1+ |
| A11 | GND | Ground | Signal and Power Ground Reference |
| A12 | GBE0_MDI0- | Digital | Gigabit Ethernet 0 MDI Differential Pair 0- |
| A13 | GBE0_MDI0+ | Digital | Gigabit Ethernet 0 MDI Differential Pair 0+ |
| A14 | GBE0_CTREF | Analog | Gigabit Ethernet Magnetics Center Tap Reference Voltage |
| A15 | SUS_S3# | Digital | ACPI S3 Suspend-to-RAM Sleep Control Output (Active Low) |
| A16 | SATA0_TX+ | Digital | Serial ATA Channel 0 Transmit Differential Pair (TX+) |
| A17 | SATA0_TX- | Digital | Serial ATA Channel 0 Transmit Differential Pair (TX-) |
| A18 | SUS_S4# | Digital | ACPI S4 Suspend-to-Disk Sleep Control Output (Active Low) |
| A19 | SATA0_RX+ | Digital | Serial ATA Channel 0 Receive Differential Pair (RX+) |
| A20 | SATA0_RX- | Digital | Serial ATA Channel 0 Receive Differential Pair (RX-) |
| A21 | GND | Ground | Signal and Power Ground Reference |
| A22 | PCIE_TX15+ | Digital | PCI Express Lane 15 Transmit Differential Pair (+) |
| A23 | PCIE_TX15- | Digital | PCI Express Lane 15 Transmit Differential Pair (-) |
| A24 | SUS_S5# | Digital | ACPI S5 Soft-Off Power State Control Output (Active Low) |
| A25 | PCIE_TX14+ | Digital | PCI Express Lane 14 Transmit Differential Pair (+) |
| A26 | PCIE_TX14- | Digital | PCI Express Lane 14 Transmit Differential Pair (-) |
| A27 | BATLOW# | Digital | Battery Low Voltage Input Indication from Carrier (Active Low) |
| A28 | SATA_ACT# | Digital | Serial ATA Activity Indicator LED (Open Collector Active Low) |
| A29 | RSVD | NC | Reserved Pin - Do Not Connect |
| A30 | RSVD | NC | Reserved Pin - Do Not Connect |
| A31 | GND | Ground | Signal and Power Ground Reference |
| A32 | RSVD | NC | Reserved Pin - Do Not Connect |
| A33 | RSVD | NC | Reserved Pin - Do Not Connect |
| A34 | BIOS_DIS0#/ESPI_SAFS | Digital | BIOS Boot Device Selection Strap 0 / eSPI Slave Attached Flash Sharing (SAFS) |
| A35 | THRMTRIP# | Digital | Processor Thermal Trip Catastrophic Over-temperature Output (Active Low) |
| A36 | PCIE_TX13+ | Digital | PCI Express Lane 13 Transmit Differential Pair (+) |
| A37 | PCIE_TX13- | Digital | PCI Express Lane 13 Transmit Differential Pair (-) |
| A38 | GND | Ground | Signal and Power Ground Reference |
| A39 | PCIE_TX12+ | Digital | PCI Express Lane 12 Transmit Differential Pair (+) |
| A40 | PCIE_TX12- | Digital | PCI Express Lane 12 Transmit Differential Pair (-) |
| A41 | GND | Ground | Signal and Power Ground Reference |
| A42 | USB2- | Digital | USB 2.0 Port 2 High-Speed Differential Data (-) |
| A43 | USB2+ | Digital | USB 2.0 Port 2 High-Speed Differential Data (+) |
| A44 | USB_2_3_OC# | Digital | USB Over-Current Fault Sense for Ports 2_3 (Active Low) |
| A45 | USB0- | Digital | USB 2.0 Port 0 High-Speed Differential Data (-) |
| A46 | USB0+ | Digital | USB 2.0 Port 0 High-Speed Differential Data (+) |
| A47 | VCC_RTC | Power | Real Time Clock Battery Power Input (+2.0V to +3.3V) |
| A48 | RSVD | NC | Reserved Pin - Do Not Connect |
| A49 | GBE0_SDP | Digital | Gigabit Ethernet 0 Software-Definable Pin (IEEE 1588 / 1PPS) |
| A50 | LPC_SERIRQ/ESPI_CS1# | Digital | LPC Serialized Interrupt Request / eSPI Secondary Chip Select 1 |
| A51 | GND | Ground | Signal and Power Ground Reference |
| A52 | PCIE_TX5+ | Digital | PCI Express Lane 5 Transmit Differential Pair (+) |
| A53 | PCIE_TX5- | Digital | PCI Express Lane 5 Transmit Differential Pair (-) |
| A54 | GPI0 | Digital | General Purpose Input 0 (Multiplexed with SD Card Data 0) |
| A55 | PCIE_TX4+ | Digital | PCI Express Lane 4 Transmit Differential Pair (+) |
| A56 | PCIE_TX4- | Digital | PCI Express Lane 4 Transmit Differential Pair (-) |
| A57 | GND | Ground | Signal and Power Ground Reference |
| A58 | PCIE_TX3+ | Digital | PCI Express Lane 3 Transmit Differential Pair (+) |
| A59 | PCIE_TX3- | Digital | PCI Express Lane 3 Transmit Differential Pair (-) |
| A60 | GND | Ground | Signal and Power Ground Reference |
| A61 | PCIE_TX2+ | Digital | PCI Express Lane 2 Transmit Differential Pair (+) |
| A62 | PCIE_TX2- | Digital | PCI Express Lane 2 Transmit Differential Pair (-) |
| A63 | GPI1 | Digital | General Purpose Input 1 (Multiplexed with SD Card Data 1) |
| A64 | PCIE_TX1+ | Digital | PCI Express Lane 1 Transmit Differential Pair (+) |
| A65 | PCIE_TX1- | Digital | PCI Express Lane 1 Transmit Differential Pair (-) |
| A66 | GND | Ground | Signal and Power Ground Reference |
| A67 | GPI2 | Digital | General Purpose Input 2 (Multiplexed with SD Card Data 2) |
| A68 | PCIE_TX0+ | Digital | PCI Express Lane 0 Transmit Differential Pair (+) |
| A69 | PCIE_TX0- | Digital | PCI Express Lane 0 Transmit Differential Pair (-) |
| A70 | GND | Ground | Signal and Power Ground Reference |
| A71 | PCIE_TX8+ | Digital | PCI Express Lane 8 Transmit Differential Pair (+) |
| A72 | PCIE_TX8- | Digital | PCI Express Lane 8 Transmit Differential Pair (-) |
| A73 | GND | Ground | Signal and Power Ground Reference |
| A74 | PCIE_TX9+ | Digital | PCI Express Lane 9 Transmit Differential Pair (+) |
| A75 | PCIE_TX9- | Digital | PCI Express Lane 9 Transmit Differential Pair (-) |
| A76 | GND | Ground | Signal and Power Ground Reference |
| A77 | PCIE_TX10+ | Digital | PCI Express Lane 10 Transmit Differential Pair (+) |
| A78 | PCIE_TX10- | Digital | PCI Express Lane 10 Transmit Differential Pair (-) |
| A79 | GND | Ground | Signal and Power Ground Reference |
| A80 | GND | Ground | Signal and Power Ground Reference |
| A81 | PCIE_TX11+ | Digital | PCI Express Lane 11 Transmit Differential Pair (+) |
| A82 | PCIE_TX11- | Digital | PCI Express Lane 11 Transmit Differential Pair (-) |
| A83 | GND | Ground | Signal and Power Ground Reference |
| A84 | NCSI_TX_EN | Digital | NC-SI Transmit Synchronous Enable Input |
| A85 | GPI3 | Digital | General Purpose Input 3 (Multiplexed with SD Card Data 3) |
| A86 | RSVD | NC | Reserved Pin - Do Not Connect |
| A87 | RSVD | NC | Reserved Pin - Do Not Connect |
| A88 | PCIE_CLK_REF+ | Digital | PCI Express 100 MHz Differential Reference Clock Output (+) |
| A89 | PCIE_CLK_REF- | Digital | PCI Express 100 MHz Differential Reference Clock Output (-) |
| A90 | GND | Ground | Signal and Power Ground Reference |
| A91 | SPI_POWER | Power | Dedicated +3.3V Power Output for Carrier SPI Flash |
| A92 | SPI_MISO | Digital | SPI Master In Slave Out - Serial Data from Carrier Flash to Module |
| A93 | GPO0 | Digital | General Purpose Output 0 (Multiplexed with SD Card Clock SD_CLK) |
| A94 | SPI_CLK | Digital | SPI Serial Clock Output from Module to Carrier BIOS Flash |
| A95 | SPI_MOSI | Digital | SPI Master Out Slave In - Serial Data from Module to Carrier Flash |
| A96 | TPM_PP | Digital | Trusted Platform Module (TPM) Physical Presence Hardware Input (Active High) |
| A97 | TYPE10# | Digital | Carrier Detection Strap for Type 10 Module (Pulled low with 47k on Type 10) |
| A98 | SER0_TX | Digital | General Purpose Asynchronous Serial Port 0 Transmit Serial Data Output |
| A99 | SER0_RX | Digital | General Purpose Asynchronous Serial Port 0 Receive Serial Data Input |
| A100 | GND | Ground | Signal and Power Ground Reference |
| A101 | SER1_TX | Digital | General Purpose Serial Port 1 / CAN Bus Transmit Serial Data Output (CAN_TX alternate) |
| A102 | SER1_RX | Digital | General Purpose Serial Port 1 / CAN Bus Receive Serial Data Input (CAN_RX alternate) |
| A103 | LID# | Digital | ACPI Notebook Lid Closure Switch Input (Active Low) |
| A104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| A110 | GND | Ground | Signal and Power Ground Reference |
| B1 | GND | Ground | Signal and Power Ground Reference |
| B2 | GBE0_ACT# | Digital | Gigabit Ethernet 0 Activity Indicator (Active Low) |
| B3 | LPC_FRAME#/ESPI_CS0# | Digital | LPC Cycle Frame Indicator / eSPI Primary Chip Select 0 (Active Low) |
| B4 | LPC_AD0/ESPI_IO_0 | Digital | LPC Multiplexed Address/Data Bit 0 / eSPI Bidirectional I/O Bit 0 |
| B5 | LPC_AD1/ESPI_IO_1 | Digital | LPC Multiplexed Address/Data Bit 1 / eSPI Bidirectional I/O Bit 1 |
| B6 | LPC_AD2/ESPI_IO_2 | Digital | LPC Multiplexed Address/Data Bit 2 / eSPI Bidirectional I/O Bit 2 |
| B7 | LPC_AD3/ESPI_IO_3 | Digital | LPC Multiplexed Address/Data Bit 3 / eSPI Bidirectional I/O Bit 3 |
| B8 | LPC_DRQ0#/ESPI_ALERT0# | Digital | LPC DMA Request 0 / eSPI Alert 0 (Active Low) |
| B9 | LPC_DRQ1#/ESPI_ALERT1# | Digital | LPC DMA Request 1 / eSPI Alert 1 (Active Low) |
| B10 | LPC_CLK/ESPI_CK | Digital | LPC Bus 33 MHz Clock Output / eSPI Bus Clock |
| B11 | GND | Ground | Signal and Power Ground Reference |
| B12 | PWRBTN# | Digital | Power Button Input (Active Low falling edge, wakes system from S5) |
| B13 | SMB_CK | Digital | System Management Bus (SMBus) Bidirectional Clock Line |
| B14 | SMB_DAT | Digital | System Management Bus (SMBus) Bidirectional Data Line |
| B15 | SMB_ALERT# | Digital | System Management Bus (SMBus) Alert Interrupt Input (Active Low) |
| B16 | SATA1_TX+ | Digital | Serial ATA Channel 1 Transmit Differential Pair (TX+) |
| B17 | SATA1_TX- | Digital | Serial ATA Channel 1 Transmit Differential Pair (TX-) |
| B18 | SUS_STAT#/ESPI_RESET# | Digital | System Suspend Status Output / eSPI Bus Reset (Active Low) |
| B19 | SATA1_RX+ | Digital | Serial ATA Channel 1 Receive Differential Pair (RX+) |
| B20 | SATA1_RX- | Digital | Serial ATA Channel 1 Receive Differential Pair (RX-) |
| B21 | GND | Ground | Signal and Power Ground Reference |
| B22 | PCIE_RX15+ | Digital | PCI Express Lane 15 Receive Differential Pair (+) |
| B23 | PCIE_RX15- | Digital | PCI Express Lane 15 Receive Differential Pair (-) |
| B24 | PWR_OK | Digital | Power OK Status Input from Carrier Power Supply (+3.3V/+5V/+12V within regulation) |
| B25 | PCIE_RX14+ | Digital | PCI Express Lane 14 Receive Differential Pair (+) |
| B26 | PCIE_RX14- | Digital | PCI Express Lane 14 Receive Differential Pair (-) |
| B27 | WDT | Digital | Hardware Watchdog Timer Timeout Output Event |
| B28 | RSVD | NC | Reserved Pin - Do Not Connect |
| B29 | RSVD | NC | Reserved Pin - Do Not Connect |
| B30 | RSVD | NC | Reserved Pin - Do Not Connect |
| B31 | GND | Ground | Signal and Power Ground Reference |
| B32 | SPKR | Digital | PC Speaker Tone Generator Digital Output |
| B33 | I2C_CK | Digital | General Purpose Multi-Master I2C Bus Clock Output |
| B34 | I2C_DAT | Digital | General Purpose Multi-Master I2C Bus Bidirectional Data Line |
| B35 | THRM# | Digital | Thermal Alert Event Input to Module (Active Low) |
| B36 | PCIE_RX13+ | Digital | PCI Express Lane 13 Receive Differential Pair (+) |
| B37 | PCIE_RX13- | Digital | PCI Express Lane 13 Receive Differential Pair (-) |
| B38 | GND | Ground | Signal and Power Ground Reference |
| B39 | PCIE_RX12+ | Digital | PCI Express Lane 12 Receive Differential Pair (+) |
| B40 | PCIE_RX12- | Digital | PCI Express Lane 12 Receive Differential Pair (-) |
| B41 | GND | Ground | Signal and Power Ground Reference |
| B42 | USB3- | Digital | USB 2.0 Port 3 High-Speed Differential Data (-) |
| B43 | USB3+ | Digital | USB 2.0 Port 3 High-Speed Differential Data (+) |
| B44 | USB_0_1_OC# | Digital | USB Over-Current Fault Sense for Ports 0_1 (Active Low) |
| B45 | USB1- | Digital | USB 2.0 Port 1 High-Speed Differential Data (-) |
| B46 | USB1+ | Digital | USB 2.0 Port 1 High-Speed Differential Data (+) |
| B47 | ESPI_EN# | Digital | Carrier Strap to Enable eSPI Mode (Pulled to GND) vs LPC Mode (Unconnected) |
| B48 | USB0_HOST_PRSNT | Digital | USB Port 0 Client Host Presence Detection Input |
| B49 | SYS_RESET# | Digital | System Reset Button Input (Active Low request for system reboot) |
| B50 | CB_RESET# | Digital | Carrier Board Reset Output from Module (Active Low reset to carrier components) |
| B51 | GND | Ground | Signal and Power Ground Reference |
| B52 | PCIE_RX5+ | Digital | PCI Express Lane 5 Receive Differential Pair (+) |
| B53 | PCIE_RX5- | Digital | PCI Express Lane 5 Receive Differential Pair (-) |
| B54 | GPO1 | Digital | General Purpose Output 1 (Multiplexed with SD Card Command SD_CMD) |
| B55 | PCIE_RX4+ | Digital | PCI Express Lane 4 Receive Differential Pair (+) |
| B56 | PCIE_RX4- | Digital | PCI Express Lane 4 Receive Differential Pair (-) |
| B57 | GPO2 | Digital | General Purpose Output 2 (Multiplexed with SD Card Write Protect SD_WP) |
| B58 | PCIE_RX3+ | Digital | PCI Express Lane 3 Receive Differential Pair (+) |
| B59 | PCIE_RX3- | Digital | PCI Express Lane 3 Receive Differential Pair (-) |
| B60 | GND | Ground | Signal and Power Ground Reference |
| B61 | PCIE_RX2+ | Digital | PCI Express Lane 2 Receive Differential Pair (+) |
| B62 | PCIE_RX2- | Digital | PCI Express Lane 2 Receive Differential Pair (-) |
| B63 | GPO3 | Digital | General Purpose Output 3 (Multiplexed with SD Card Card Detect SD_CD#) |
| B64 | PCIE_RX1+ | Digital | PCI Express Lane 1 Receive Differential Pair (+) |
| B65 | PCIE_RX1- | Digital | PCI Express Lane 1 Receive Differential Pair (-) |
| B66 | WAKE0# | Digital | PCI Express Bus Wake-up Event Input (Active Low) |
| B67 | WAKE1# | Digital | General Purpose Wake-up Event Input (Active Low) |
| B68 | PCIE_RX0+ | Digital | PCI Express Lane 0 Receive Differential Pair (+) |
| B69 | PCIE_RX0- | Digital | PCI Express Lane 0 Receive Differential Pair (-) |
| B70 | GND | Ground | Signal and Power Ground Reference |
| B71 | PCIE_RX8+ | Digital | PCI Express Lane 8 Receive Differential Pair (+) |
| B72 | PCIE_RX8- | Digital | PCI Express Lane 8 Receive Differential Pair (-) |
| B73 | GND | Ground | Signal and Power Ground Reference |
| B74 | PCIE_RX9+ | Digital | PCI Express Lane 9 Receive Differential Pair (+) |
| B75 | PCIE_RX9- | Digital | PCI Express Lane 9 Receive Differential Pair (-) |
| B76 | GND | Ground | Signal and Power Ground Reference |
| B77 | PCIE_RX10+ | Digital | PCI Express Lane 10 Receive Differential Pair (+) |
| B78 | PCIE_RX10- | Digital | PCI Express Lane 10 Receive Differential Pair (-) |
| B79 | GND | Ground | Signal and Power Ground Reference |
| B80 | GND | Ground | Signal and Power Ground Reference |
| B81 | PCIE_RX11+ | Digital | PCI Express Lane 11 Receive Differential Pair (+) |
| B82 | PCIE_RX11- | Digital | PCI Express Lane 11 Receive Differential Pair (-) |
| B83 | GND | Ground | Signal and Power Ground Reference |
| B84 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B85 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B86 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B87 | VCC_5V_SBY | Power | Standby +5V DC Power Input for Suspend States |
| B88 | BIOS_DIS1# | Digital | BIOS Boot Device Selection Strap 1 Input |
| B89 | NCSI_RX_ER | Digital | NC-SI Receive Error Output |
| B90 | GND | Ground | Signal and Power Ground Reference |
| B91 | NCSI_CLK_IN | Digital | NC-SI 50 MHz Interface Reference Clock Input |
| B92 | NCSI_RXD1 | Digital | NC-SI Receive Data Bit 1 (Network Controller to BMC) |
| B93 | NCSI_RXD0 | Digital | NC-SI Receive Data Bit 0 (Network Controller to BMC) |
| B94 | NCSI_CRS_DV | Digital | NC-SI Carrier Sense / Receive Data Valid Output |
| B95 | NCSI_TXD1 | Digital | NC-SI Transmit Data Bit 1 (BMC to Network Controller) |
| B96 | NCSI_TXD0 | Digital | NC-SI Transmit Data Bit 0 (BMC to Network Controller) |
| B97 | SPI_CS# | Digital | SPI Chip Select for Carrier Board BIOS Flash (Active Low) |
| B98 | NCSI_ARB_IN | Digital | NC-SI Hardware Arbitration Token Ring Input |
| B99 | NCSI_ARB_OUT | Digital | NC-SI Hardware Arbitration Token Ring Output |
| B100 | GND | Ground | Signal and Power Ground Reference |
| B101 | FAN_PWMOUT | Digital | Pulse Width Modulated Fan Speed Control Output |
| B102 | FAN_TACHIN | Digital | Fan Tachometer Speed Sensor Input (Two pulses per revolution) |
| B103 | SLEEP# | Digital | ACPI Sleep Button / Hibernate Switch Input (Active Low) |
| B104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| B110 | GND | Ground | Signal and Power Ground Reference |
| C1 | GND | Ground | Signal and Power Ground Reference |
| C2 | GND | Ground | Signal and Power Ground Reference |
| C3 | USB_SSRX0- | Digital | USB 3.0 SuperSpeed Port 0 Receive Differential Pair (-) |
| C4 | USB_SSRX0+ | Digital | USB 3.0 SuperSpeed Port 0 Receive Differential Pair (+) |
| C5 | GND | Ground | Signal and Power Ground Reference |
| C6 | USB_SSRX1- | Digital | USB 3.0 SuperSpeed Port 1 Receive Differential Pair (-) |
| C7 | USB_SSRX1+ | Digital | USB 3.0 SuperSpeed Port 1 Receive Differential Pair (+) |
| C8 | GND | Ground | Signal and Power Ground Reference |
| C9 | USB_SSRX2- | Digital | USB 3.0 SuperSpeed Port 2 Receive Differential Pair (-) |
| C10 | USB_SSRX2+ | Digital | USB 3.0 SuperSpeed Port 2 Receive Differential Pair (+) |
| C11 | GND | Ground | Signal and Power Ground Reference |
| C12 | USB_SSRX3- | Digital | USB 3.0 SuperSpeed Port 3 Receive Differential Pair (-) |
| C13 | USB_SSRX3+ | Digital | USB 3.0 SuperSpeed Port 3 Receive Differential Pair (+) |
| C14 | GND | Ground | Signal and Power Ground Reference |
| C15 | 10G_PHY_MDC_SCL3 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 3 |
| C16 | 10G_PHY_MDC_SCL2 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 2 |
| C17 | 10G_SDP2 | Digital | 10G Controller Software-Definable Pin 2 (IEEE 1588 1PPS) |
| C18 | GND | Ground | Signal and Power Ground Reference |
| C19 | PCIE_RX6+ | Digital | PCI Express Lane 6 Receive Differential Pair (+) |
| C20 | PCIE_RX6- | Digital | PCI Express Lane 6 Receive Differential Pair (-) |
| C21 | GND | Ground | Signal and Power Ground Reference |
| C22 | PCIE_RX7+ | Digital | PCI Express Lane 7 Receive Differential Pair (+) |
| C23 | PCIE_RX7- | Digital | PCI Express Lane 7 Receive Differential Pair (-) |
| C24 | 10G_INT2 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 2 |
| C25 | GND | Ground | Signal and Power Ground Reference |
| C26 | 10G_KR_RX3+ | Digital | 10GBASE-KR Port 3 Receive Input Differential Pair (+) |
| C27 | 10G_KR_RX3- | Digital | 10GBASE-KR Port 3 Receive Input Differential Pair (-) |
| C28 | GND | Ground | Signal and Power Ground Reference |
| C29 | 10G_KR_RX2+ | Digital | 10GBASE-KR Port 2 Receive Input Differential Pair (+) |
| C30 | 10G_KR_RX2- | Digital | 10GBASE-KR Port 2 Receive Input Differential Pair (-) |
| C31 | GND | Ground | Signal and Power Ground Reference |
| C32 | 10G_SFP_SDA3 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 3 |
| C33 | 10G_SFP_SDA2 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 2 |
| C34 | 10G_PHY_RST_23 | Digital | 10G Optical PHY Hardware Reset Output for Ports 23 (Active Low) |
| C35 | 10G_PHY_RST_01 | Digital | 10G Optical PHY Hardware Reset Output for Ports 01 (Active Low) |
| C36 | 10G_LED_SDA | Digital | 10G MAC LED and PHY Strapping Serialized I2C Bus Data |
| C37 | 10G_LED_SCL | Digital | 10G MAC LED and PHY Strapping Serialized I2C Bus Clock |
| C38 | 10G_SFP_SDA1 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 1 |
| C39 | 10G_SFP_SDA0 | Digital | 10G SFP+ Optical Transceiver I2C Management Data Port 0 |
| C40 | 10G_SDP0 | Digital | 10G Controller Software-Definable Pin 0 (IEEE 1588 1PPS) |
| C41 | GND | Ground | Signal and Power Ground Reference |
| C42 | 10G_KR_RX1+ | Digital | 10GBASE-KR Port 1 Receive Input Differential Pair (+) |
| C43 | 10G_KR_RX1- | Digital | 10GBASE-KR Port 1 Receive Input Differential Pair (-) |
| C44 | GND | Ground | Signal and Power Ground Reference |
| C45 | 10G_PHY_MDC_SCL1 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 1 |
| C46 | 10G_PHY_MDC_SCL0 | Digital | 10G PHY Management Data Clock (MDIO MDC) / I2C Clock for Port Pair 0 |
| C47 | 10G_INT0 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 0 |
| C48 | GND | Ground | Signal and Power Ground Reference |
| C49 | 10G_KR_RX0+ | Digital | 10GBASE-KR Port 0 Receive Input Differential Pair (+) |
| C50 | 10G_KR_RX0- | Digital | 10GBASE-KR Port 0 Receive Input Differential Pair (-) |
| C51 | GND | Ground | Signal and Power Ground Reference |
| C52 | PCIE_RX16+ | Digital | PCI Express Lane 16 Receive Differential Pair (+) |
| C53 | PCIE_RX16- | Digital | PCI Express Lane 16 Receive Differential Pair (-) |
| C54 | TYPE0# | Digital | Module Pin-out Type Identification Strap 0 Output to Carrier |
| C55 | PCIE_RX17+ | Digital | PCI Express Lane 17 Receive Differential Pair (+) |
| C56 | PCIE_RX17- | Digital | PCI Express Lane 17 Receive Differential Pair (-) |
| C57 | TYPE1# | Digital | Module Pin-out Type Identification Strap 1 Output to Carrier |
| C58 | PCIE_RX18+ | Digital | PCI Express Lane 18 Receive Differential Pair (+) |
| C59 | PCIE_RX18- | Digital | PCI Express Lane 18 Receive Differential Pair (-) |
| C60 | GND | Ground | Signal and Power Ground Reference |
| C61 | PCIE_RX19+ | Digital | PCI Express Lane 19 Receive Differential Pair (+) |
| C62 | PCIE_RX19- | Digital | PCI Express Lane 19 Receive Differential Pair (-) |
| C63 | RSVD | NC | Reserved Pin - Do Not Connect |
| C64 | RSVD | NC | Reserved Pin - Do Not Connect |
| C65 | PCIE_RX20+ | Digital | PCI Express Lane 20 Receive Differential Pair (+) |
| C66 | PCIE_RX20- | Digital | PCI Express Lane 20 Receive Differential Pair (-) |
| C67 | RAPID_SHUTDOWN | Digital | Emergency Rapid Shutdown Trigger Input for NV-DIMM / data protection |
| C68 | PCIE_RX21+ | Digital | PCI Express Lane 21 Receive Differential Pair (+) |
| C69 | PCIE_RX21- | Digital | PCI Express Lane 21 Receive Differential Pair (-) |
| C70 | GND | Ground | Signal and Power Ground Reference |
| C71 | PCIE_RX22+ | Digital | PCI Express Lane 22 Receive Differential Pair (+) |
| C72 | PCIE_RX22- | Digital | PCI Express Lane 22 Receive Differential Pair (-) |
| C73 | GND | Ground | Signal and Power Ground Reference |
| C74 | PCIE_RX23+ | Digital | PCI Express Lane 23 Receive Differential Pair (+) |
| C75 | PCIE_RX23- | Digital | PCI Express Lane 23 Receive Differential Pair (-) |
| C76 | GND | Ground | Signal and Power Ground Reference |
| C77 | RSVD | NC | Reserved Pin - Do Not Connect |
| C78 | PCIE_RX24+ | Digital | PCI Express Lane 24 Receive Differential Pair (+) |
| C79 | PCIE_RX24- | Digital | PCI Express Lane 24 Receive Differential Pair (-) |
| C80 | GND | Ground | Signal and Power Ground Reference |
| C81 | PCIE_RX25+ | Digital | PCI Express Lane 25 Receive Differential Pair (+) |
| C82 | PCIE_RX25- | Digital | PCI Express Lane 25 Receive Differential Pair (-) |
| C83 | RSVD | NC | Reserved Pin - Do Not Connect |
| C84 | GND | Ground | Signal and Power Ground Reference |
| C85 | PCIE_RX26+ | Digital | PCI Express Lane 26 Receive Differential Pair (+) |
| C86 | PCIE_RX26- | Digital | PCI Express Lane 26 Receive Differential Pair (-) |
| C87 | GND | Ground | Signal and Power Ground Reference |
| C88 | PCIE_RX27+ | Digital | PCI Express Lane 27 Receive Differential Pair (+) |
| C89 | PCIE_RX27- | Digital | PCI Express Lane 27 Receive Differential Pair (-) |
| C90 | GND | Ground | Signal and Power Ground Reference |
| C91 | PCIE_RX28+ | Digital | PCI Express Lane 28 Receive Differential Pair (+) |
| C92 | PCIE_RX28- | Digital | PCI Express Lane 28 Receive Differential Pair (-) |
| C93 | GND | Ground | Signal and Power Ground Reference |
| C94 | PCIE_RX29+ | Digital | PCI Express Lane 29 Receive Differential Pair (+) |
| C95 | PCIE_RX29- | Digital | PCI Express Lane 29 Receive Differential Pair (-) |
| C96 | GND | Ground | Signal and Power Ground Reference |
| C97 | RSVD | NC | Reserved Pin - Do Not Connect |
| C98 | PCIE_RX30+ | Digital | PCI Express Lane 30 Receive Differential Pair (+) |
| C99 | PCIE_RX30- | Digital | PCI Express Lane 30 Receive Differential Pair (-) |
| C100 | GND | Ground | Signal and Power Ground Reference |
| C101 | PCIE_RX31+ | Digital | PCI Express Lane 31 Receive Differential Pair (+) |
| C102 | PCIE_RX31- | Digital | PCI Express Lane 31 Receive Differential Pair (-) |
| C103 | GND | Ground | Signal and Power Ground Reference |
| C104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| C110 | GND | Ground | Signal and Power Ground Reference |
| D1 | GND | Ground | Signal and Power Ground Reference |
| D2 | GND | Ground | Signal and Power Ground Reference |
| D3 | USB_SSTX0- | Digital | USB 3.0 SuperSpeed Port 0 Transmit Differential Pair (-) |
| D4 | USB_SSTX0+ | Digital | USB 3.0 SuperSpeed Port 0 Transmit Differential Pair (+) |
| D5 | GND | Ground | Signal and Power Ground Reference |
| D6 | USB_SSTX1- | Digital | USB 3.0 SuperSpeed Port 1 Transmit Differential Pair (-) |
| D7 | USB_SSTX1+ | Digital | USB 3.0 SuperSpeed Port 1 Transmit Differential Pair (+) |
| D8 | GND | Ground | Signal and Power Ground Reference |
| D9 | USB_SSTX2- | Digital | USB 3.0 SuperSpeed Port 2 Transmit Differential Pair (-) |
| D10 | USB_SSTX2+ | Digital | USB 3.0 SuperSpeed Port 2 Transmit Differential Pair (+) |
| D11 | GND | Ground | Signal and Power Ground Reference |
| D12 | USB_SSTX3- | Digital | USB 3.0 SuperSpeed Port 3 Transmit Differential Pair (-) |
| D13 | USB_SSTX3+ | Digital | USB 3.0 SuperSpeed Port 3 Transmit Differential Pair (+) |
| D14 | GND | Ground | Signal and Power Ground Reference |
| D15 | 10G_PHY_MDIO_SDA3 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 3 |
| D16 | 10G_PHY_MDIO_SDA2 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 2 |
| D17 | 10G_SDP3 | Digital | 10G Controller Software-Definable Pin 3 (IEEE 1588 1PPS) |
| D18 | GND | Ground | Signal and Power Ground Reference |
| D19 | PCIE_TX6+ | Digital | PCI Express Lane 6 Transmit Differential Pair (+) |
| D20 | PCIE_TX6- | Digital | PCI Express Lane 6 Transmit Differential Pair (-) |
| D21 | GND | Ground | Signal and Power Ground Reference |
| D22 | PCIE_TX7+ | Digital | PCI Express Lane 7 Transmit Differential Pair (+) |
| D23 | PCIE_TX7- | Digital | PCI Express Lane 7 Transmit Differential Pair (-) |
| D24 | 10G_INT3 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 3 |
| D25 | RSVD | NC | Reserved Pin - Do Not Connect |
| D26 | 10G_KR_TX3+ | Digital | 10GBASE-KR Port 3 Transmit Output Differential Pair (+) |
| D27 | 10G_KR_TX3- | Digital | 10GBASE-KR Port 3 Transmit Output Differential Pair (-) |
| D28 | GND | Ground | Signal and Power Ground Reference |
| D29 | 10G_KR_TX2+ | Digital | 10GBASE-KR Port 2 Transmit Output Differential Pair (+) |
| D30 | 10G_KR_TX2- | Digital | 10GBASE-KR Port 2 Transmit Output Differential Pair (-) |
| D31 | GND | Ground | Signal and Power Ground Reference |
| D32 | 10G_SFP_SCL3 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 3 |
| D33 | 10G_SFP_SCL2 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 2 |
| D34 | 10G_PHY_CAP_23 | Digital | 10G PHY Configuration Mode Capability Input Strap for Ports 23 (Low: I2C/MDIO, High: MDIO only) |
| D35 | 10G_PHY_CAP_01 | Digital | 10G PHY Configuration Mode Capability Input Strap for Ports 01 (Low: I2C/MDIO, High: MDIO only) |
| D36 | RSVD | NC | Reserved Pin - Do Not Connect |
| D37 | RSVD | NC | Reserved Pin - Do Not Connect |
| D38 | 10G_SFP_SCL1 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 1 |
| D39 | 10G_SFP_SCL0 | Digital | 10G SFP+ Optical Transceiver I2C Management Clock Port 0 |
| D40 | 10G_SDP1 | Digital | 10G Controller Software-Definable Pin 1 (IEEE 1588 1PPS) |
| D41 | GND | Ground | Signal and Power Ground Reference |
| D42 | 10G_KR_TX1+ | Digital | 10GBASE-KR Port 1 Transmit Output Differential Pair (+) |
| D43 | 10G_KR_TX1- | Digital | 10GBASE-KR Port 1 Transmit Output Differential Pair (-) |
| D44 | GND | Ground | Signal and Power Ground Reference |
| D45 | 10G_PHY_MDIO_SDA1 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 1 |
| D46 | 10G_PHY_MDIO_SDA0 | Digital | 10G PHY Management Data I/O (MDIO) / I2C Data for Port Pair 0 |
| D47 | 10G_INT1 | Digital | 10G PHY / SFP+ Optical Module Interrupt Input 1 |
| D48 | GND | Ground | Signal and Power Ground Reference |
| D49 | 10G_KR_TX0+ | Digital | 10GBASE-KR Port 0 Transmit Output Differential Pair (+) |
| D50 | 10G_KR_TX0- | Digital | 10GBASE-KR Port 0 Transmit Output Differential Pair (-) |
| D51 | GND | Ground | Signal and Power Ground Reference |
| D52 | PCIE_TX16+ | Digital | PCI Express Lane 16 Transmit Differential Pair (+) |
| D53 | PCIE_TX16- | Digital | PCI Express Lane 16 Transmit Differential Pair (-) |
| D54 | RSVD | NC | Reserved Pin - Do Not Connect |
| D55 | PCIE_TX17+ | Digital | PCI Express Lane 17 Transmit Differential Pair (+) |
| D56 | PCIE_TX17- | Digital | PCI Express Lane 17 Transmit Differential Pair (-) |
| D57 | TYPE2# | Digital | Module Pin-out Type Identification Strap 2 Output to Carrier |
| D58 | PCIE_TX18+ | Digital | PCI Express Lane 18 Transmit Differential Pair (+) |
| D59 | PCIE_TX18- | Digital | PCI Express Lane 18 Transmit Differential Pair (-) |
| D60 | GND | Ground | Signal and Power Ground Reference |
| D61 | PCIE_TX19+ | Digital | PCI Express Lane 19 Transmit Differential Pair (+) |
| D62 | PCIE_TX19- | Digital | PCI Express Lane 19 Transmit Differential Pair (-) |
| D63 | RSVD | NC | Reserved Pin - Do Not Connect |
| D64 | RSVD | NC | Reserved Pin - Do Not Connect |
| D65 | PCIE_TX20+ | Digital | PCI Express Lane 20 Transmit Differential Pair (+) |
| D66 | PCIE_TX20- | Digital | PCI Express Lane 20 Transmit Differential Pair (-) |
| D67 | GND | Ground | Signal and Power Ground Reference |
| D68 | PCIE_TX21+ | Digital | PCI Express Lane 21 Transmit Differential Pair (+) |
| D69 | PCIE_TX21- | Digital | PCI Express Lane 21 Transmit Differential Pair (-) |
| D70 | GND | Ground | Signal and Power Ground Reference |
| D71 | PCIE_TX22+ | Digital | PCI Express Lane 22 Transmit Differential Pair (+) |
| D72 | PCIE_TX22- | Digital | PCI Express Lane 22 Transmit Differential Pair (-) |
| D73 | GND | Ground | Signal and Power Ground Reference |
| D74 | PCIE_TX23+ | Digital | PCI Express Lane 23 Transmit Differential Pair (+) |
| D75 | PCIE_TX23- | Digital | PCI Express Lane 23 Transmit Differential Pair (-) |
| D76 | GND | Ground | Signal and Power Ground Reference |
| D77 | RSVD | NC | Reserved Pin - Do Not Connect |
| D78 | PCIE_TX24+ | Digital | PCI Express Lane 24 Transmit Differential Pair (+) |
| D79 | PCIE_TX24- | Digital | PCI Express Lane 24 Transmit Differential Pair (-) |
| D80 | GND | Ground | Signal and Power Ground Reference |
| D81 | PCIE_TX25+ | Digital | PCI Express Lane 25 Transmit Differential Pair (+) |
| D82 | PCIE_TX25- | Digital | PCI Express Lane 25 Transmit Differential Pair (-) |
| D83 | RSVD | NC | Reserved Pin - Do Not Connect |
| D84 | GND | Ground | Signal and Power Ground Reference |
| D85 | PCIE_TX26+ | Digital | PCI Express Lane 26 Transmit Differential Pair (+) |
| D86 | PCIE_TX26- | Digital | PCI Express Lane 26 Transmit Differential Pair (-) |
| D87 | GND | Ground | Signal and Power Ground Reference |
| D88 | PCIE_TX27+ | Digital | PCI Express Lane 27 Transmit Differential Pair (+) |
| D89 | PCIE_TX27- | Digital | PCI Express Lane 27 Transmit Differential Pair (-) |
| D90 | GND | Ground | Signal and Power Ground Reference |
| D91 | PCIE_TX28+ | Digital | PCI Express Lane 28 Transmit Differential Pair (+) |
| D92 | PCIE_TX28- | Digital | PCI Express Lane 28 Transmit Differential Pair (-) |
| D93 | GND | Ground | Signal and Power Ground Reference |
| D94 | PCIE_TX29+ | Digital | PCI Express Lane 29 Transmit Differential Pair (+) |
| D95 | PCIE_TX29- | Digital | PCI Express Lane 29 Transmit Differential Pair (-) |
| D96 | GND | Ground | Signal and Power Ground Reference |
| D97 | RSVD | NC | Reserved Pin - Do Not Connect |
| D98 | PCIE_TX30+ | Digital | PCI Express Lane 30 Transmit Differential Pair (+) |
| D99 | PCIE_TX30- | Digital | PCI Express Lane 30 Transmit Differential Pair (-) |
| D100 | GND | Ground | Signal and Power Ground Reference |
| D101 | PCIE_TX31+ | Digital | PCI Express Lane 31 Transmit Differential Pair (+) |
| D102 | PCIE_TX31- | Digital | PCI Express Lane 31 Transmit Differential Pair (-) |
| D103 | GND | Ground | Signal and Power Ground Reference |
| D104 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D105 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D106 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D107 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D108 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D109 | VCC_12V | Power | Primary +12V DC Module Power Supply Input |
| D110 | GND | Ground | Signal and Power Ground Reference |