# CH340G USB to Serial UART Bridge Controller

- **Manufacturer**: WCH (Jiangsu Qinheng)
- **Type**: Chip
- **Year**: 2012
- **URL (German)**: https://pinoutdb.org/component/ch340g
- **URL (English)**: https://pinoutdb.org/en/component/ch340g
- **Description**: USB serial converter, UART, SOIC-16
- **Datasheets & Links**:
  - [CH340G Datasheet (PDF)](http://www.datasheet5.com/pdf-local-2195953) (datasheet)

## View: SOIC-16 Top View (Package: dip)

| Pin | Signal Name | Type | Alternative Functions / Description |
| :--- | :--- | :--- | :--- |
| 1 | GND | Ground | System Ground (0V) [Ground] |
| 2 | TXD | Digital | UART Transmit Data Output (from USB host to target device) [UART] |
| 3 | RXD | Digital | UART Receive Data Input (from target device to USB host) [UART] |
| 4 | V3 | Power | Internal 3.3V Regulator Output — connect 100nF bypass cap to GND; do not drive external loads [Power], 3.3V I/O Supply Input — when operating at 3.3V, connect V3 to VCC and omit the bypass cap [Power] |
| 5 | UD+ | Digital | USB Data Positive (D+) — connect directly to USB connector D+ [USB] |
| 6 | UD- | Digital | USB Data Negative (D-) — connect directly to USB connector D- [USB] |
| 7 | XI | Digital | Crystal Oscillator Input — connect 12MHz crystal; load capacitors (22pF typical) to GND [Oscillator] |
| 8 | XO | Digital | Crystal Oscillator Output — connect to crystal only; do not load [Oscillator] |
| 9 | CTS | Digital | CTS — Clear to Send Hardware Flow Control Input (Active Low) [UART] |
| 10 | DSR | Digital | DSR — Data Set Ready Input (Active Low, RS-232 modem status signal) [UART] |
| 11 | RI | Digital | RI — Ring Indicator Input (Active Low, RS-232 modem status signal) [UART] |
| 12 | DCD | Digital | DCD — Data Carrier Detect Input (Active Low, RS-232 modem status signal) [UART] |
| 13 | DTR | Digital | DTR — Data Terminal Ready Output (Active Low; commonly used to reset Arduino bootloader) [UART] |
| 14 | RTS | Digital | RTS — Request to Send Hardware Flow Control Output (Active Low) [UART] |
| 15 | R232 | Digital | RS-232 Level Enable — pull HIGH via 100kΩ to enable auxiliary RS-232 charge-pump circuit for ±12V output swing; leave LOW or float for TTL-level operation [Control] |
| 16 | VCC | Power | Positive Power Supply (3.3V or 5V; add 100nF bypass cap to GND) [Power] |


---
Source: PinoutDatabase (https://pinoutdb.org). Verify against the manufacturer datasheet before production use.